6 log management – PLANET GSD-1002M User Manual
Page 46

User’s Manual of GSD-1002M
The page includes the following fields:
Object
Description
SNTP Server Address
Type the IP address or domain name of the SNTP server.
Type the port number of the SNTP.
Server Port
Buttons
: Click to apply changes.
Figure 4-2-11 SNTP
Server Informations
page screenshot
The page includes the following fields:
Object
Description
SNTP Server Address
Display the current SNTP server sddress.
Display the current SNTP server port.
Server Port
4.2.6 Log Management
The Managed Switch log management is provided here. The local logs allow you to configure and limit system messages that
are logged to flash or RAM memory. The default is for event levels 0 to 3 to be logged to flash and levels 0 to 6 to be logged to
RAM. The following table lists the event levels of the Managed Switch:
Level
Severity Name
Description
7
Debug
Debugging messages
6
Informational
Informational messages only
5
Notice
Normal but significant condition, such as cold start
4
Warning
Warning conditions (e.g., return false, unexpected return)
3
Error
Error conditions (e.g., invalid input, default used)
2
Critical
Critical conditions (e.g., memory allocation, or free memory
error - resource exhausted)
1
Alert
Immediate action needed
0
Emergency
System unusable
46