beautypg.com

Enterasys Networks Enterasys Platinum Distributed Forwarding Engine 7G4285-49 User Manual

Page 65

background image

Using LANVIEW

DFE-Platinum Series Hardware Installation Guide 4-7

RX/TX LED Indications in PoE Port Status Mode

RX/TX

Green/Off

There is a connection to a
PD. There is 48 Vdc at the
RJ45 connector.

None.

Off/Red

Port is off due to overload.
The attached device
exceeded maximum load
according to 802.3af
standard PoE device power
classification.

1. Check the attached PD to see if it is

defective and drawing too much
power for its Power Classification.

2. Check Ethernet cable from the PD

for short circuits.

3. Contact Enterasys Networks for

technical support.

Red/Off

Port is off due to PoE power
management. Port may be
turned off due to priority or
other administration
configuration.

None

RX/TX

Off/Off

Port is off for other reason.

1. There is no connection to a PD.

2. If the DFE module is in an N5

chassis, ensure that the N5 is
turned on.

3. If connected to an N-POE Power

System, ensure that it is turned on.

4. If the power is being received from

an N-POE Power System, check the
48 Vdc power cable connection.

5. Swap 48 Vdc power cable with a

known good one.

6. If you still have a problem, contact

Enterasys Networks for technical
support.

Table 4-1 LANVIEW LEDs (continued)

LED

Color

State

Recommended Action

This manual is related to the following products: