Page 64
Using LANVIEW
4-6 Troubleshooting
RX/TX Indications in Standard Mode
RX
(Receive)
Off
No link. No activity. Port
enabled or disabled.
None.
Green
Solid. Link present, port
enabled, no traffic is being
received by the interface.
None.
Amber
Flashing. Link present, port
enabled, traffic is being
received by the interface.
None.
Red
Blinking. Indicates
collisions. This indication is
only supported on 10/100
ports.
Contact Enterasys Networks for
technical support.
TX
(Transmit)
Off
Port enabled, but no activity.
If it is known that the port should be
active and is not, contact
Enterasys Networks for technical
support.
Green
Flashing. Indicates data
transmission activity. Rate of
flashing indicates the data
rate.
None.
Red
Flashing. Fault or Error
(collision).
None, unless there is a high rate of
activity. In this case, check for network
configuration problems or a defective
device.
Table 4-1 LANVIEW LEDs (continued)
LED
Color
State
Recommended Action