KEPCO HSP Series Operator Manual User Manual
Kepco, Hsp series, Model

IMPORTANT NOTES:
1)
This manual is valid for the following Model and associated serial numbers:
MODEL
SERIAL NO.
REV. NO.
2)
A Change Page may be included at the end of the manual. All applicable changes and
revision number changes are documented with reference to the equipment serial num-
bers. Before using this Instruction Manual, check your equipment serial number to identify
your model. If in doubt, contact your nearest Kepco Representative, or the Kepco Docu-
mentation Office in New York, (718) 461-7000, requesting the correct revision for your par-
ticular model and serial number.
3)
The contents of this manual are protected by copyright. Reproduction of any part can be
made only with the specific written permission of Kepco, Inc.
Data subject to change without notice.
KEPCO
®
THE POWER SUPPLIER™
MODEL
O P E R ATO R ’ S M A N U A L
KEPCO INC.
ORDER NO.
REV. NO.
KEPCO, INC.
131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
email: [email protected]
World Wide Web: http://www.kepcopower.com
An ISO 9001 Company.
©2014, KEPCO, INC
P/N 243-0851-g
HSP SERIES
1000 AND 1500 WATT SWITCHING POWER SUPPLY
VOLTAGE/CURRENT STABILIZED DC SOURCE
HSP SERIES
POWER SUPPLY
Document Outline
- SECTION 1 - INTRODUCTION
- 1.1 Scope of Manual
- 1.2 General Description
- 1.3 Specifications
- TABLE 1-1. Model Parameters
- TABLE 1-2. General Specifications
- FIGURE 1-2. HSP (All), Nominal Mains Voltage: Temperature Derating,
- FIGURE 1-3. HSP 1500W, Low Mains Voltage: Temperature, Power Derating
- FIGURE 1-4. Outline Drawing
- 1.4 Miscellaneous Features
- 1.4.1 Control/Programming
- 1.4.2 Status Indicators/Flags
- 1.4.3 Setpoint Monitors:
- 1.4.4 Remote Error Sensing:
- 1.4.5 Load Sharing:
- 1.4.6 Load Monitor:
- 1.4.7 Auxiliary Supply:
- 1.4.8 Overcurrent/Undervoltage Protection:
- 1.4.9 Current Walk-in:
- 1.4.10 Remote Reset:
- 1.5 Options
- 1.5.1 Meters (M Suffix):
- 1.5.2 Battery Chargers (B Suffix):
- 1.5.3 Internal Blocking Diode (R Suffix):
- 1.6 Accessories
- TABLE 1-3. Accessories
- SECTION 2 - INSTALLATION
- 2.1 Unpacking and Inspection
- 2.2 Terminations and Controls
- FIGURE 2-1. HSP Series Front Panel Controls and Indicators
- FIGURE 2-2. Configuration Switch Functions
- FIGURE 2-3. HSP Series Rear Panel Connections
- TABLE 2-1. I/O Connector Pin Assignments
- 2.3 Source Power Requirements
- 2.4 Cooling
- 2.5 Preliminary Operational Check
- 2.6 Installation
- 2.7 Wiring Instructions
- 2.7.1 Safety Grounding
- 2.7.2 Source Power Connections
- 2.7.3 D-C Output Grounding
- 2.7.4 Power Supply/Load Interface
- 2.7.5 Load Connection - General
- 2.7.5.1 Load Connection - Method I (Local Error Sensing)
- FIGURE 2-4. Load Connection - Method I (Local Error Sensing)
- 2.7.5.2 Load Connection - Method II (Remote Error Sensing)
- FIGURE 2-5. Load Connection - Method II (Remote Error Sensing)
- 2.7.5.3 Load Connection - Method III (Series Connection)
- FIGURE 2-6. Load Connection - Method III - (Series Connection)
- 2.7.5.4 Load Connection - Method IV (Parallel Operation)
- FIGURE 2-7. Load Connection - Method IV (Parallel/Redundant Operation with Hot-Swap)
- 2.7.5.4.1 Redundancy and Hot Swap Applications
- 2.7.6 Load Sharing
- 2.7.7 Signal Connections
- 2.8 Mechanical Keying
- 2.9 Retaining Latches
- SECTION 3 - OPERATING INSTRUCTIONS
- 3.1 Operating Configuration
- 3.2 Remote Error Sense
- 3.3 Output Voltage Programming
- FIGURE 3-1. External Resistance Programming of Output Voltage
- FIGURE 3-2. External Voltage Programming of Output Voltage
- 3.4 Output Voltage Range
- 3.5 Current Limit Programming
- FIGURE 3-3. External Voltage Programming of Current Limit
- 3.6 Current Limit Programming Range
- 3.7 Setpoint Monitors
- 3.8 Overvoltage Protection Adjustment
- 3.9 Current Limit Characteristic
- 3.10 Current Walk-in Circuit
- FIGURE 3-4. Current Walk-in Characteristic
- 3.11 5VAUX Floating Supply
- 3.12 Remote Inhibit/Remote Reset Controls
- FIGURE 3-5. Remote Inhibit Control Operation
- 3.13 Module Current Monitor
- 3.14 Status Indicators and Status Flags
- TABLE 3-1. Status Indicators and Flags
- 3.14.1 Power Indicator/Source Power Status Flags
- FIGURE 3-6. Timing Diagram for POWER and DCFAIL Status
- 3.14.2 DCFAIL Indicator and Output Status Flags
- TABLE 3-2. Fault Detector Operation
- 3.14.3 OVERTEMP Indicator and Status Flags
- 3.14.4 FANFAIL Indicator and Status Flags
- 3.15 Front Panel Meter (M Option) Operation
- 3.15.1 Voltmeter Operation
- 3.15.2 Ammeter Operation
- 3.15.3 Parallel/redundant Operation
- 3.16 Battery (B Option) Operation
- TABLE 3-3. B Option Fault Detection Window
- FIGURE 3-7. HSP M (Meter) Option and B (Battery Charger) Option, Front Panel