84
Orion X Installation and Operations Manual
Serial Interface
The Orion X allows switching via a serial interface (RS232).
Detailed information for the serial interface and the corresponding switching commands are available in
form of an API (application programming interface) upon request.
Power Up and Power Down Functions
This section deals with Power functions of the Orion X.
Restart
The Orion X can be restarted through the OSD and the Java Tool.
Restarting through the OSD
1. Select Configuration > Restart Matrix or Restart IO Board in the main menu to restart either the
matrix or the I/O boards.
2. Confirm the selection with button YES.
The matrix and the I/O boards will be restarted with the current settings.
Restarting through the Java Tool
Select Matrix > Restart Matrix in the menu bar.
The Orion X will be restarted with the current settings.
Factory Reset
It is only possible to reset the system to factory defaults through the OSD.
When a factory reset is done, all current settings and all configurations stored in the matrix will be lost.
This also applies to the network parameters (reset to DHCP) and the admin password.
If a firmware update has been done since the delivery, the matrix will be set to the defaults defined in that
firmware.
Resetting through the OSD
1. Select Configuration > Factory Reset in the main menu.
2. Confirm the selection with the YES button.
The Orion X will be reset to factory settings.
Power Down
Press the on/off rocker switch at the main sockets of the power supply units to start up or power down
the matrix.