Rose Electronics Orion X-series User Manual
Page 113

Orion X Installation and Operations Manual
105
Fiber
A point-to-point connection is necessary. Operation with multiple patch panels is allowed. Routing over
active network components, such as Ethernet Hubs, Matrixes or Routers, is not allowed.
Type of Interconnect Cable
(Cable notations according to VDE)
Type of cable
Specifications
Single-mode 9μm
Two fibers 9μm
I-V(ZN)H 2E9 (in-house patch cable)
I-V(ZN)HH 2E9 (in-house breakout cable)
I/AD(ZN)H 4E9 (in-house or outdoor breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with protection against rodents)
Multi-mode 50μm
Two fibers 50μm
I-V(ZN)H 2G50 (in-house patch cable)
I/AD(ZN)H 4G50 (in-house or outdoor breakout cable, resistant)
Multi-mode 62.5μm
Two fibers 62.5μm
I-V(ZN)HH 2G62,5 (in-house breakout cable)
A/DQ(ZN)B2Y 4G62,5 (outdoor cable, with protection against rodents)
Note: Only use Single-mode connection cables for fiber connections that are based on 3G SFPs.
Maximum Acceptable Cable Length
Type of cable
1.25 Gbps
3.125 Gbps
Single-mode 9μm
32,800 ft (10,000 m) 16,400 ft (5,000 m )
Multi-mode 50μm (OM3) 3,280 ft (1,000 m)
1,640 ft (500 m)
Multi-mode 50μm
1,300 ft (400 m)
650 ft (200 m)
Multi-mode 62.5μm
650 ft (200 m)
325 ft (100 m)
If single-mode SFPs are used with multi-mode fibers, you normally can increase the maximum acceptable
cable length.
Type of Connector
Type of connector LC Connector
Coaxial
A point-to-point connection is necessary.
Type of Interconnect Cable
Cable Type
Specifications
Mini coaxial cable AWG 18 RG 6
impedance 75 Ω
Maximum Acceptable Cable Length
Band width Maximum acceptable cable length
0.270 Gbit/s 1,312 ft (400 m)
1.485 Gbit/s 459 ft (140 m)
2.970 Gbit/s 394 ft (120 m)
Type of Connector
Type of connector Mini BNC Connector