18-6
MSO1000Z/DS1000Z User’s Guide
Measure
Cursor
Manual Mode
Voltage Deviation between Cursors (△V)
Time Deviation between Cursors (△T)
Reciprocal of △T (Hz) (1/△T)
Track Mode
Voltage and Time Values of the Waveform
Point
Auto Mode
Allow to display cursors during auto
measurement
Auto
Measurement
Analog channel:
Period, Frequency, Rise Time, Fall Time, Positive Pulse Width,
Negative Pulse Width, Positive Duty Cycle, Negative Duty Cycle,
tVmax, tVmin, Positive Rate, Negative Rate, Delay 12 , Delay
12 , Phase 12 , Phase 12 , Maximum, Minimum,
Peak-Peak Value, Top Value, Bottom Value, Amplitude, Upper
Value, Middle Value, Lower Value, Average, Vrms, Overshoot,
Pre-shoot, Area, Period Area, Period Vrms, Variance
Digital channel:
Period, Frequency, Positive Pulse Width, Negative Pulse Width,
Positive Duty Cycle, Negative Duty Cycle, Delay 12 , Delay
12 , Phase 12 , Phase 12
Number of
Measurements
Display 5 measurements at the same time.
Measurement
Range
Screen or cursor
Measurement
Statistic
Average, Max, Min, Standard Deviation, Number of
Measurements
Frequency
Counter
Hardware 6 bit frequency counter
(channels are selectable)
Math Operation
Waveform
Operation
A+B, A-B, A×B, A/B, FFT, A&&B, A||B, A^B, !A, Intg, Diff, Sqrt,
Lg, Ln, Exp, Abs
FFT Window
Function
Rectangle, Hanning, Blackman, Hamming, Flat Top, Triangle
FFT Display
Half, Full
FFT Vertical
Scale
dB/dBm, Vrms
Number of
Buses for
Decoding
2
Decoding Type
Parallel (standard), RS232/UART (option), I2C (option), SPI
(option)