RISCO Group ProSYS – ACM User Manual
Page 18

18
Advanced Communication Module
Events Report Over IP
In addition to local events printing (using a local printer connected to
the ProSYS), the ACM will enable storing of unlimited amount of
events over Ethernet resources, which can be used for backup and
analysis. (Not applicable for the ProSYS UK version).
Quick Key
Parameter
[5][7][6][1]
ENABLE
Provision for optional functionality
[5][7][6][2]
E-LOG IP ADDRESS
Provision for optional functionality
[5][7][6][3]
E-LOG IP PORT
Provision for optional functionality
Getting ACM IP Address
In some installations the ACM IP address might be configured to be
dynamic (see quick key [4][0][3] for DHCP IP address). In this case the
host server will assign the IP address.
Sometimes it might be needed to get the IP address, from someone on
the premises in order to maintain a proper operation of the ACM over
the network.
To get the ACM IP address:
From the ProSYS user menu enter Maintenance by pressing [*][4]
Enter the Grand Master Code followed by the
/
/
.
Press [0][3] for the option “GET ACM IP”.
Press
/
/
to confirm; the desired ACM IP address
appears on the LCD.