Advanced Communication Module

11

Programming the ACM - General

The ACM Module is programmed in a similar manner to all ProSYS
accessories, via the LCD keypad or via the UD Software, locally or
remotely.
The following information refers to ACM programming features added for
ACM functionality. We recommend reading and fully understanding the
ProSYS Installation and User Manuals, before programming the ACM.

NOTE:

The term “Provision for” in the following programming instructions, refers to optional

additional functionality!
The quick keys and programming locations for the ProSYS UK version are marked in
Italic text

Adding Deleting the ACM

To add/delete the ACM module, perform the following steps:
1. From the ProSYS installer menu, enter the ADD/Delete option

(Quick Key [7][1]).

2. Press [9][3] to access the ACM module option.

3. Use the

/

/

key to select either NONE (no ACM)

or ACM1 (ACM installed).

4. Press

/

/

to confirm your selection.

Defining MS Connection Type

Connection between the ProSYS panel and the monitoring station
(MS) is configured via the DIALER (Digicom) Menu.
From the ProSYS installer menu, access the Dialer menu [5].
1. Press [1] to access the Link Up sub-menu.
2. Use the quick key combinations described in the table below to

access your desired option and configure your system as desired.

Quick Key

Parameter

[5][1][1]

MS LINK UP

Defines the link up parameters between the
monitoring station receiver and the ProSYS panel.

[5][1][1][1]

MS 1 LINK UP

Defines the link up parameters used for the first
monitoring station.

NOTE:

3 linkups are available.