RISCO Group ProSYS – ACM User Manual
Page 15

Advanced Communication Module
15
Defining the ACM Control Parameters
From the Dialer menu [5], press [0][3] to enter the ACM Control
parameters Menu .
Quick Key
Parameter
[5][0][3][1]
UK: [8][1][2][1]
ACM CONFIGURATION
Defines the ACM parameters configuration.
[5][0][3][1][1]
UK: [8][1][2][1][1]
CLIENT ATN
Provision for optional functionality
[5][0][3][1][2]
UK: [8][1][2][1][2]
DHCP IP
Defines whether the IP address, which the ACM
refers to, is static or dynamic
.
YES: The ACM refers to an IP address provided
by the DHCP
NO: The ACM refers to the ACM static IP Address
defined by quick key [5][0][2][1].
Default: NO
[5][0][3][2]
UK: [8][1][2][2]
ACM U/D CONFIGURATION
Defines the authorization type when using the U/D
software application over the Ethernet network;
i
Disabled
i
Full Control (ENABLED)
Default: Full Control
[5][0][3][3]
UK: [8][1][2][3]
ACM AUX1 CONFIGURATION
Defines the authorization type when using the
received application by the ACM auxiliary 1
protocol (Modbus).
i
Disabled
i
Full Control (ENABLED)
Default: Disabled
[5][0][3][4]
UK: [8][1][2][4]
ACM AUX2 CONFIGURATION
Provision for optional functionality
[5][0][3][5]
UK: [8][1][2][5]
ACM AUX3 CONFIGURATION