beautypg.com

2 specifying log contents – Emerson Network Router User Manual

Page 68

background image

62

ProLink

®

II Software for Micro Motion

®

Transmitters

Data Logger

Note: The log file can become very large if you choose Time Interval and log for a long period of
time. Be sure to set the Update Rate accordingly.

Figure 7-1

Data Logger

7.2.2

Specifying log contents

Variables that are available for inclusion are shown in the

Parameters

group. To add data to be

included in the log:

1. Click the

ProcessVars

,

Diagnostics

,

OutputVars

, or

AllVars

tab.

2. Highlight the variable you want to include in the log.

3. Click

Add

.

Variables that are set to be included are shown in the

Current Log

group. To remove data from

inclusion in the log:

1. Highlight the variable you want to remove.

2. Click

Remove

.

3. To remove all variables from the

Current Log

list, click

Clear All

.