Extron rgb 168xi – Extron Electronics RGB 168xi User Manual
Page 21
RGB 168xi
xi
xi
xi
xi • Installation and Operation
2-11
Adapter plate installation must be performed
by authorized service personnel only.
Follow these steps to install adapter plates.
1
. Make sure that the power is removed from the interface
by disconnecting the AC power cord from the unit.
2
. Open the cover of the interface (the top half of the
enclosure), as shown below. Remove the screws from
the enclosure, and lift the cover straight up.
Do not touch any switches or electronic
components inside the interface. Doing so
could damage the interface.
Extron
RGB 168xi
RGB 168 xi
INPUTS
AU
DIO
ANALOG
UNSWITCHED
600 W
ATTS
MAX.
MIN/MAX
UNIVERSAL INTERF
ACE
W /ADSP
ID PIN 14
ID PIN 11
BUFFERED LOCAL
MONIT
OR OUTPUT
Remove #8 Screw
(4 Plcs) Each Side
and Bracket, if Present
Remove (12)
Screws
Lift Cover
Straight Up
3
. Remove the blank plates from the interface by
unscrewing the nuts that fasten the plates to the inside
of the enclosure.
4
. Route the adapter output cables through the rear panel
cable holes and clamps into the enclosure and out the
front panel plate openings, as shown on the facing page.
5
. Attach the output cables to the rear connectors of the
front panel adapter plates. Soldering will be required
for some connectors.