beautypg.com

5 clearing the sm-ezmotion module memory – Emerson P/N 400361-00 User Manual

Page 137

background image

Diagnostics www.emersonct.com 123

Figure 119:

Status Online Tab

Many of the views in PowerTools Pro have Online tab that
contain parameters related to that View when online with
the drive.

13.4 Clearing SLX.dF trip after
installing SM-EZMotion module

After installing a SM-EZMotion module for the first time, the
Unidrive SP will display a SLX.dF trip (where X is the slot
number that the SM-EZMotion module is in). This trip
occurs because the drive detects the module type in the
slot has changed. This trip will occur on each successive
power up until the drive parameter database has been
saved. To save the drive parameter database, follow the
instructions below.

Saving the Drive Parameters

When changing a parameter in Menu 0, the new value is

saved automatically when pressing the Mode button

to return to parameter view mode from parameter edit
mode.

If parameters have been changed in the advanced menus,
then the change will not be saved automatically. A save
function must be carried out.

The procedure for saving the parameters is as follows:

1.Enter the value 1000 in MM.00, where MM is any menu

number.

2. Press the red Reset button.

13.5 Clearing the SM-EZMotion
module memory

The SM-EZMotion module has a function that allows the
user to clear the module memory. Doing so will erase the
configuration stored in the module. To procedure for
erasing the module configuration is as follows:

1.Navigate to parameter 18.01 on the keypad

2. Press the Mode button

to enter parameter edit

mode

3. Enter the value 19237

4. Press the Mode button

again to return to parameter

view mode

5. Remove AC power from the Unidrive SP

6. Restore power to the Unidrive SP

After performing the clear memory sequence, the
SM-EZMotion module will cause a SLX.Er trip (where X
indicates the slot number that the SM-EZMotion module is
fitted in). The Error Code for the SM-EZMotion module will
be “107 – No Program Error” indicating that the module has
no configuration stored in it. Download a new configuration
using PowerTools Pro EZ to clear the trip.

M

M d

St

/R

t

M

M