beautypg.com

Emerson P/N 400361-00 User Manual

Page 133

background image

Diagnostics www.emersonct.com 119

135

Y

Program Error - Math Addition

Overflow

Math addition operation in user
program has resulted in an overflow of
the resultant parameter

Verify that the sum of all the operands in
addition formulas will not result in a value
in the following range:
-2

31

< SUM < 2

31

-1

136

Y

Program Error - Math Divide By Zero

Formula in user program causes a
divide by zero

Make sure that the denominator in all
division formulas is not equal to zero.

137

Y

Program Error - Math Divide Operand

Too Large

138

Y

Program Error - Math Multiplication

Normalization Failed

Normalization of multiplication
parameters in user program has failed

139

Y

Program Error - Math Multiplication

Operand Too Large

140

Y

Program Error - Overflow

141

Y

Program Error - Math Subtraction

Overflow

142

Y

Program Error - Math Stack Overflow

User Program math process stack has
overflown

143

Y

File Corruption Error - Consult Factory

144

Y

File Corruption Error - Consult Factory

145

Y

File Corruption Error - Consult Factory

146

Y

File Corruption Error - Consult Factory

147

Y

Program Error - Flash Memory Size

Exceeded

User configuration exceeds available
flash memory size

Eliminate any unused Indexes or
Programs and re-download the
PowerTools Pro configuration

148

Y

Program Error - RAM Memory Size

Exceeded

User configuration exceeds available
RAM memory size

Eliminate any unused Indexes or
Programs and re-download the
PowerTools Pro configuration

153

Y

File Corruption Error - Consult Factory

154

Y

File Corruption Error - Consult Factory

155

Y

File Corruption Error - Consult Factory

156

Y

Program Error - Too Many Wait For

Instructions

No more than nine arguments in Wait
for Instruction

Limit # of arguments and redownloads

157

Y

File Corruption Error - Consult Factory

158

Y

File Corruption Error - Consult Factory

159

Y

File Corruption Error - Consult Factory

160

Y

File Corruption Error - Consult Factory

161

Y

File Corruption Error - Consult Factory

162

Y

File Corruption Error - Consult Factory

163

Y

File Corruption Error - Consult Factory

164

Y

File Corruption Error - Consult Factory

165

Y

File Corruption Error - Consult Factory

166

Y

Program Error - EZMotion Parameter

Write Out of Range

Value written to SM-EZMotion
parameter in user program is out of
range

171

Y

Invalid Slot 1 Selection

Option module selected for Slot 1 in
PowerTools Pro file does not match
actual module type fitted

Switch module located in Slot 1 to match
module type selected in PowerTools Pro
file. Alternatively, update the PowerTools
Pro configuration to match the module
type actually fitted, and then re-download
the configuration.

Error Code

(x.50)

Cause

Trip?

Error

Possible Reason

Possible Solution