Table D.9 – Drive Faults
Fault
Content
Cause
Solution
BUS
Option PCB communications error
Communication is not established between
PROFIBUS-DP Master and the drive.
• Check PROFIBUS-DP communication LED display.
EF0
Option PCB external fault
Drive received an external fault command
from the Option PCB
• Check multi-function input settings
• Check PLC or controller program
• Eliminate cause of fault (machine device in fault state)
OPE05
Command selection fault
Parameter B1-01 is set to Option PCB and
no card is detected
• Install Option PCB
• Reprogram B1-01
• Replace the Option PCB
OPE06
Control mode selection fault
Parameter B1-02 is set to Option PCB and
no card is detected
• Install Option PCB
• Reprogram B1-02
• Replace the Option PCB
CPF20
Option PCB fault
Faulty CN2 connection
• Power cycle the drive
• Reseat the Option PCB
• Replace the Option PCB
• Replace the inverter
CPF21
Option PCB self-diagnostics fault
CPF22
Option PCB ID code fault
CPF23
Watch dog timer fault
Faulty Option PCB
• Replace the Option PCB