Page 61

Appendix A CONSTANTS LIST
E-51
U1-10
Input Terminal Status
[Input Term Sts]
−
Q
Shows input ON/OFF status.
*1: Can be selected by H1-XX.
• Output signal level at multi-function analog output: Dis-
abled.
U1-11
Output Terminal Status
[Output Term Sts]
−
Q
Shows output ON/OFF status.
*2: Can be selected by H2-XX.
• Output signal level at multi-function analog output: Dis-
abled.
U1-12
Operation Status
[Drive Ope Sts]
−
Q
VS-656DC5 operating status
• Output signal level at multi-function analog output: Dis-
abled.
U1-13
Cumulative Operation Time
[Elapsed Time]
1 H
Q
• Output signal level at multi-function analog output: Dis-
abled.
U1-14
Software No.
[FLASH ID]
−
B
(Manufacturer's ID number)
U1-17
Input Power Factor
[Power Factor]
1%
B
• Output signal level at multi-function analog output
10 V: 100%
(0 to +10 V output)
U1-18
Effective Current Reference
[Real Current]
0.1%
B
• Output signal level at multi-function analog output
10 V: Rated current
(0 to +10 V output)
U1-19
Ineffective Current Reference
[Reactive Current]
0.1%
B
• Output signal level at multi-function analog output
10 V: Rated current
(0 to +10 V output)
(cont’d)
Constant No.
Name
[Display]
Unit
Access
Level
Remarks
= 00000000
1: RUN-SB (terminal 1) ON
1: STOP (terminal 2) ON
1: External fault (terminal 3) ON
*1
1: Fault reset (terminal 4) ON
*1
1: Not used (terminals 5 to 7) ON
*1
1: External baseblock (terminal 8) ON
*1
= 00000000
1: Running (terminals 9-10) ON
*2
1: CREADY (terminals 25 to 27) ON
*2
1: During MCON (terminals 26-37) ON
*2
1: Not used (always 0)
1: Fault output (terminals 18/19-20) ON
= 00000000
1: Running
1: Not used (always 0)
1: Reset input ON
1: Not used (always 0)
1: VS-656DC5 ready
1: Minor fault detected
1: Major fault detected