5 wiring precautions, Control circuit wiring – Yaskawa Varispeed-656 DC5 User Manual
Page 32

E-22
3.5
Wiring Precautions
The external interconnection wiring must be performed with following procedures. After
completing VS-656DC5 interconnections, be sure to check that the connections are correct.
Never use control circuit buzzer check.
Control Circuit Wiring
Separate control circuit wiring from main circuit wiring and other power cables.
Separate wiring for control circuit terminals from other control circuits or main circuit wir-
ings.
Wiring distance should be 50 m or less.
Insert the wire into the lower part of the terminal block and connect it tightly with a screw-
driver.
Fig. 9 Control Circuit Terminal Wiring
Use twisted-pair shielded wire for the control circuit wire and connect the shielded sheath to
VS-656DC5 terminal E. (Refer to Fig. 10.)
Fig. 10 Shielded Wire Termination
0.6 mm max.
3.5 mm max.
5.5 mm
Wire sheath strip length must be 5.5 mm.
Screwdriver Blade Width
Do not connect here.
Connect to shielded sheath
terminal E at VS-656DC5.
Shielded sheath
Armor
Insulate with tape.
- Tag Generator (30 pages)
- MP3300iec (82 pages)
- 1000 Hz High Frequency (18 pages)
- 1000 Series (7 pages)
- PS-A10LB (39 pages)
- iQpump Micro User Manual (300 pages)
- 1000 Series Drive Option - Digital Input (30 pages)
- 1000 Series Drive Option - CANopen (39 pages)
- 1000 Series Drive Option - Analog Monitor (27 pages)
- 1000 Series Drive Option - CANopen Technical Manual (37 pages)
- 1000 Series Drive Option - CC-Link (38 pages)
- 1000 Series Drive Option - CC-Link Technical Manual (36 pages)
- 1000 Series Drive Option - DeviceNet (37 pages)
- 1000 Series Drive Option - DeviceNet Technical Manual (81 pages)
- 1000 Series Drive Option - MECHATROLINK-II (32 pages)
- 1000 Series Drive Option - Digital Output (31 pages)
- 1000 Series Drive Option - MECHATROLINK-II Technical Manual (41 pages)
- 1000 Series Drive Option - Profibus-DP (35 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (36 pages)
- Z1000U HVAC MATRIX Drive Quick Start (378 pages)
- 1000 Series Operator Mounting Kit NEMA Type 4X (20 pages)
- 1000 Series Drive Option - Profibus-DP Technical Manual (44 pages)
- CopyUnitManager (38 pages)
- 1000 Series Option - JVOP-182 Remote LED (58 pages)
- 1000 Series Option - PG-X3 Line Driver (31 pages)
- SI-EN3 Technical Manual (68 pages)
- JVOP-181 (22 pages)
- JVOP-181 USB Copy Unit (2 pages)
- SI-EN3 (54 pages)
- MECHATROLINK-III (35 pages)
- SI-ET3 (49 pages)
- EtherNet/IP (50 pages)
- SI-EM3 (51 pages)
- 1000-Series Option PG-E3 Motor Encoder Feedback (33 pages)
- 1000-Series Option SI-EP3 PROFINET (56 pages)
- PROFINET (62 pages)
- AC Drive 1000-Series Option PG-RT3 Motor (45 pages)
- SI-EP3 PROFINET Technical Manual (53 pages)
- A1000 Drive Option - BACnet MS/TP (48 pages)
- 120 Series I/O Modules (308 pages)
- A1000 12-Pulse (92 pages)
- A1000 Drive Software Technical Manual (16 pages)
- A1000 Quick Start (2 pages)
- JUNMA Series AC SERVOMOTOR (1 page)
- A1000 Option DI-101 120 Vac Digital Input Option (24 pages)