Yaskawa P7 to P1000 User Manual
Page 26

13 Appendix 2 Parameter Cross Reference
26
YASKAWA PL.P1000.01 P7 to P1000 - Product Transition Guide
DC Injection
Braking
DC Injection
Braking Start
Frequency
b2-01
0.5 Hz
b2-01
0.5 Hz
—
DC Injection
Braking current
b2-02
50%
b2-02
50%
—
DC Injection
Braking Time at
Start
b2-03
0.00 s
b2-03
0.00 s
—
DC Injection
Braking Time at
Stop
b2-04
0.00 s
b2-04
0.50 s
—
Motor Pre-Heat
Current
b2-09
0%
b2-02
50%
The same current setting is used for DC injection at start and stop.
Default current is 50%
Motor Pre-Heat
Current 2
b2-10
5%
b2-02
50%
Speed Search
Speed Search
Selection
b3-01
2
b3-01
0
b3-01
b3-01
b3-24
0: Disabled
(Speed Estimation)
0: Disabled
1: Speed
Estimation
1: Enabled
(Speed Estimation)
1: Enabled
1: Speed
Estimation
b3-24
0
2: Disabled
(Current Detection)
0: Disabled
0: Current
Detection
3: Enabled
(Current Detection)
1: Enabled
0: Current
Detection
Speed Search
Operating
Current
b3-02
120%*
b3-02
120% *Determined by parameter A1-02, Control Method Selection
Speed Search
Deceleration
Time
b3-03
2.0 s
b3-03
2.0 s
—
Speed Search
Delay Time
b3-05
0.2 s
b3-05
0.2 s
—
Bi-Directional
Speed Search
Selection
b3-14
1
b3-14
1
b3-14
b3-14
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Timers
Timer Function
On-Delay Time
b4-01
0.0 s
b4-01
0.0 s
—
Timer Function
Off-Delay Time
b4-02
0.0 s
b4-02
0.0 s
—
Parameter Name
P7
P1000
Setting
Parameter
Default
Parameter
Default
P7
P1000