beautypg.com

12 appendix d - cable cross section and torque, 1 dc connection – SMA SC 100LV-560HE User Manual

Page 86

background image

Appendix D - Cable cross section and Torque

SMA Solar Technology AG

86

SC125_560HE-IEN083220

Installation Guide

12 Appendix D - Cable cross section and Torque

12.1 DC connection

(1

Screw at NH fuse holder

(2

Copper bus bar perforated

Sunny Central

DC fuses

Max. cross section

Torque

SC 100LV

5

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 125LV

5

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 150 Standard

5

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 200 Standard

5

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 200HE

5

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 250 Standard

8

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 250HE

8

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 350 Standard

12

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 350HE

12

M10

(1

up to 240 mm², slim

cable lug

30 - 35 Nm

SC 500HE

1 x Cu per pole

M12

(2

3 x 240 mm², slim

cable lug per pole

74 Nm

SC 560HE

1 x Cu per pole

M12

(2

3 x 240 mm², slim

cable lug per pole

74 Nm