Failures and Warnings

SMA Solar Technology AG

54

SC-BEN092751

User Manual

217

Error text:

DC CB tripped or door switch open

Error type 2

Cause:

• The cabinet door was opened during operation.
• The DC circuit breaker was tripped due to an internal fault.
• The reverse current monitoring system on the DC side has switched off.
• The EVR resistor's current monitoring system has tripped.

Corrective measures:

• Close the cabinet doors.
• Check the function of the door switches.
• Check the function and activation of the emergency shut-off relay.
• Check reverse current monitoring system.
• Visually inspect the chopper module and the EVR resistors.
• Contact the Sunny Central Serviceline.

220

Error text:

Release or Reset Signal faulty

Error type 2

Cause:

The release signal or confirmation signal of the inverter bridge is defective.

Corrective measures:

If this error is always present, contact the Sunny Central Serviceline.

221

Error text:

CHOPPER overtemperature

Error type 3

Cause:

• EVR resistor overtemperature.
• Defective chopper module.
• After 90 minutes, a new startup attempt occurs.

Corrective measures:

• Check resistor for dirt.
• Ventilate resistor sufficiently.
• Contact the Sunny Central Serviceline.

No.