beautypg.com

SMA SUNNY CENTRAL User Manual

Page 48

background image

Failures and Warnings

SMA Solar Technology AG

48

SC-BEN092751

User Manual

380

Error text:

SMU

Error type 1

Cause:

The string monitoring system has detected one or more faulty strings or overvoltage
protectors.

Corrective measures:

• Under "Device Set-up -> SMUs -> Devices -> Measured Values", read out the

individual string currents to detect the faulty string.

• More detailed information can be found in the Sunny String Monitor manual.

381

Error text:

ser. com. with SMU disturbed

Error type 1

Cause:

Communication failure between Sunny Central and the Sunny String Monitors.

Corrective measures:

• Check communication lines and connections.
• More detailed information can be found in the Sunny String Monitor manual.

382

Error text:

thievery solar panel

Error type 1

Cause:

Signal loop for theft detection at the Sunny String Monitor has been interrupted.

Corrective measures:

• Check string currents.
• Check signal loop.
• For further details, refer to the installation guide and user manual of the Sunny String

Monitor or Sunny String Monitor Cabinet.

No.

Description