SMA SB 3000TL-20 Installation User Manual
Page 94
![background image](https://www.manualsdir.com/files/818883/content/doc094.png)
Technical data
SMA Solar Technology AG
94
SB30TL_40TL_50TL-IA-IEN120231
Installation Guide
Features
Electronic Solar Switch (ESS)
Torque
Grid forms
DC connection
SUNCLIX DC plug connector
AC connection
Spring terminal
Display
LC graphic display
Bluetooth
Standard
RS485, galvanically isolated
optional
Multi-function relay
Standard
Electrical service life in the event of a short circuit,
with a nominal current of 35 A
A minimum of 50 switching operations
Maximum switching current
35 A
Maximum switching voltage
800 V
Maximum PV power
12 kW
Protection rating when plugged
IP65
Protection rating when unplugged
IP21
Upper lid screws
2.4 Nm
Lower lid screws
1.5 Nm
Additional ground terminal
6 Nm
SUNCLIX lock nuts
2 Nm
TN-C
Suitable
TN-S
Suitable
TN-C-S
Suitable
TT
Suitable, if U
N_PE
< 30 V