beautypg.com

SMA SB 3000TL-20 Installation User Manual

Page 40

background image

Electrical Connection

SMA Solar Technology AG

40

SB30TL_40TL_50TL-IA-IEN120231

Installation Guide

3. Check the DC connector for correct polarity and

connect it. To release the DC connectors see section
7.2 ”Opening the Inverter” (page 61).
The Sunny Boy 3000TL is equipped with input
zone A only!

4. To create the sealing on the inverter, all the DC

inputs have to be closed as follows:
– Insert the provided sealing plugs into the

unneeded DC plug connectors.
Do not insert the sealing plugs into the DC
inputs on the inverter.

– Insert the DC plug connectors with sealing plugs

into the corresponding DC inputs on the inverter.

5. Close the lid again using the 6 screws.

Tighten the screws with 1.4 Nm torque in the order
shown in the figure on the right.