Electrical Connection

SMA Solar Technology AG

34

SB30TL_40TL_50TL-IA-IEN120231

Installation Guide

• The following limit values at the DC input of the inverter must not be exceeded:

5.4.2 Conditions for the DC connection for Sunny Boy 4000TL/5000TL

The inverter has two input zones "A" and "B", each with its own MPP tracker. 2 strings can be
connected to each input zone.

maximum input voltage

Maximum input current

550 V

17.0 A

Use of Adaptors
Adaptors (branch connectors) must not be visible or freely accessible in the immediate
surroundings of the inverter.

• The DC circuit may not be interrupted by adaptors.
• Observe the procedure for disconnecting the inverter as described in section

7.2 ”Opening the Inverter” (page 61).