beautypg.com

SMA SB 3000TL-20 Installation User Manual

Page 67

background image

SMA Solar Technology AG

Maintenance and cleaning

Installation Guide

SB30TL_40TL_50TL-IA-IEN120231

67

– Push the upper and lower latches on the fan (C)

outwards and push the fan out of the fan
enclosure from the rear side.

5. Clean the fan enclosure with a soft brush, a paint brush, a cloth or pressurized air.
6. Clean the fan with a soft brush, a paint brush, or a damp cloth.

7. After cleaning, reassemble everything in reverse order.

– The arrows on the fan enclosure and the fan

must point to the right during assembly.

– The fastening clips on the right side of the fan

enclosure must catch underneath the enclosure
wall when inserting them into the inverter.

☑ The fan has been cleaned.

8. Close the inverter as described in section 7.3 ”Closing the Inverter” (page 64).
9. Check the functioning of the fan as described in the following section 8.1.2 ”Check fan (only

with Sunny Boy 4000TL/5000TL)” (page 68).

NOTICE!
Damage to the fan due to the use of compressed air.

• Do not use pressurized air to clean the fan. This can damage the fan.

This manual is related to the following products: