beautypg.com

11 technical data, 1 sunny boy 1200, Technical data – SMA SB 1200 Installation User Manual

Page 63: Sunny boy 1200

background image

SMA Solar Technology AG

Technical Data

Installation Guide

SB12-17-IA-en-52

63

11 Technical Data

11.1 Sunny Boy 1200

DC Input

* The maximum open circuit voltage, which can occur at a cell temperature of −10 °C, may not exceed the maximum input voltage.

AC Output

Maximum DC power at cos φ = 1

P

DC

1 320 W

Maximum DC voltage *

V

DC

max

400 V

MPP voltage range at 230 V AC

V

PV

100 V … 320 V

DC nominal voltage

V

DC nom

120 V

Minimum DC voltage at 230 V AC

V

DC min

100 V

Start voltage, adjustable

V

PV Start

120 V

Maximum input current

I

PV max

12.6 A

Number of MPP trackers

1

Maximum number of parallel strings

2

Voltage ripple of input voltage

V

pp

< 10 %

Internal consumption during operation

< 4 W

AC nominal power at 230 V AC, 50 Hz

P

AC nom

1 200 W

Maximum AC apparent power

S

AC max

1 200 VA

Nominal AC current

I

AC nom

5.2 A

Maximum output current

I

AC max

6.1 A

Maximum fuse protection

16 A

Harmonic distortion of output current at
AC THD voltage < 2 %,
AC power > 0.5 AC nominal power

K

IAC

< 3 %

Nominal AC voltage

V

AC nom

220 V / 230 V / 240 V

AC voltage range

V

AC

180 V … 265 V

AC grid frequency

f

AC nom

50 Hz / 60 Hz

Operating range at AC grid frequency

f

AC

50 Hz: 45.5 Hz … 54.5 Hz
60 Hz: 55.5 Hz … 64.5 Hz

Power factor at nominal AC power

cos φ

1

Overvoltage category

III

Test voltage at 50 Hz

1.7 kV

Surge testing voltage

4 kV

Surge testing voltage with serial interface

6 kV

Internal consumption in night mode

0.1 W

This manual is related to the following products: