beautypg.com

SMA SB 1200 Installation User Manual

Page 12

background image

Safety

SMA Solar Technology AG

12

SB12-17-IA-en-52

Installation Guide

NOTICE!
Damage to the inverter due to moisture and dust intrusion

If the Electronic Solar Switch is not plugged in or incorrectly plugged in during operation,
moisture and dust can penetrate the inverter.
If the Electronic Solar Switch is not correctly plugged in, this can cause contacts to wear in
the Electronic Solar Switch or the Electronic Solar Switch might fall down. This can result in
yield loss and damage to the Electronic Solar Switch.
Always plug in the Electronic Solar Switch as described in the following:

• Do not tighten the screw in the Electronic Solar Switch.
• Firmly plug in the Electronic Solar Switch until it is flush with the enclosure.
• Ensure that the maximum distance between the Electronic Solar Switch and the

enclosure is 1 mm.

Grounding the PV Generator
Comply with the local requirements for grounding the modules and the PV generator.
SMA Solar Technology AG recommends connecting the generator frame and other
electricity conducting surfaces so that there is continuous conduction and to ground them
in order to achieve maximum protection of the system and personnel.

This manual is related to the following products: