9 failure search, 1 led codes, Failure search – SMA SB 1200 Installation User Manual
Page 52: Led codes
Failure Search
SMA Solar Technology AG
52
SB12-17-IA-en-52
Installation Guide
9 Failure Search
If the inverter displays blink codes or error messages other than those described in the following
section, contact the SMA Serviceline.
In the user manual provided, you will also find a description of the display messages during operation,
the status messages and measuring channels.
Do not try to carry out repairs other than those described here. Instead, use the SMA Solar
Technology AG 24-hour replacement service (the inverter will be ready for dispatch within 24 hours
and sent to a forwarding agency) and repair service
9.1 LED Codes
Green
Red
Yellow
Status
Glows continuously
Is not glowing
Is not glowing
OK (feeding operation)
Glows continuously Is not glowing
Ground fault or varistor
defective
Glows continuously OK (initialization)
Flashes quickly
(3 x per second)
Is not glowing
Is not glowing
OK (stop)
Glows continuously Is not glowing
Ground fault or varistor
defective
Flashes slowly
(1 x per second)
Is not glowing
Is not glowing
OK (waiting, grid monitoring)
Glows continuously Is not glowing
Ground fault or varistor
defective
Briefly goes out
(Approx. 1x per
second)
Is not glowing
Is not glowing
OK (derating)
Glows continuously Is not glowing
Ground fault or varistor
defective
Is not glowing
Is not glowing
Is not glowing
OK (nighttime deactivation)
Glowing/flashing
Disturbance
Glows continuously Is not glowing
Ground fault or varistor
defective
Glowing/flashing
Ground fault or varistor
defective and disturbance