beautypg.com

9 failure search, 1 led codes, Failure search – SMA SB 1200 Installation User Manual

Page 52: Led codes

background image

Failure Search

SMA Solar Technology AG

52

SB12-17-IA-en-52

Installation Guide

9 Failure Search

If the inverter displays blink codes or error messages other than those described in the following
section, contact the SMA Serviceline.
In the user manual provided, you will also find a description of the display messages during operation,
the status messages and measuring channels.
Do not try to carry out repairs other than those described here. Instead, use the SMA Solar
Technology AG 24-hour replacement service (the inverter will be ready for dispatch within 24 hours
and sent to a forwarding agency) and repair service

9.1 LED Codes

Green

Red

Yellow

Status

Glows continuously

Is not glowing

Is not glowing

OK (feeding operation)

Glows continuously Is not glowing

Ground fault or varistor
defective

Glows continuously OK (initialization)

Flashes quickly
(3 x per second)

Is not glowing

Is not glowing

OK (stop)

Glows continuously Is not glowing

Ground fault or varistor
defective

Flashes slowly
(1 x per second)

Is not glowing

Is not glowing

OK (waiting, grid monitoring)

Glows continuously Is not glowing

Ground fault or varistor
defective

Briefly goes out
(Approx. 1x per
second)

Is not glowing

Is not glowing

OK (derating)

Glows continuously Is not glowing

Ground fault or varistor
defective

Is not glowing

Is not glowing

Is not glowing

OK (nighttime deactivation)

Glowing/flashing

Disturbance

Glows continuously Is not glowing

Ground fault or varistor
defective

Glowing/flashing

Ground fault or varistor
defective and disturbance