4 connecting the speedwire/webconnect data module – SMA SPEEDWIRE V.1.6 User Manual
Page 18
![background image](https://www.manualsdir.com/files/818468/content/doc018.png)
5 Connection
SMA Solar Technology AG
18
SWWEBCONDM-IA-en-16
Installation Manual
5.4 Connecting the Speedwire/Webconnect Data Module
Depending on the system topology you require, you must connect either one or two cables to the
Speedwire/Webconnect data module.
Requirement:
☐ The network cables must be pre-assembled in accordance with the system topology and the
cable requirements (see Section 5.2, page 15).
Additionally required material (not included in the scope of delivery):
☐ Network cable (see Section 5.2 "Cable Requirements and Information on Cable Routing",
Procedure:
2. Flip the display up until it snaps into place.
3. Unscrew the swivel nut of the cable gland on the
inverter.
4. Press the seal out of the cable gland from the inside.
1.
Danger to life due to electric shock when opening the inverter
High voltages are present in the conductive components of the inverter. Touching live
components results in death or serious injury.
• If the inverter has not yet been opened, disconnect the inverter from all voltage sources
on the AC and DC sides and open it (see the inverter installation manual). Observe the
waiting time to allow the capacitors to discharge.