beautypg.com

SMA FLX Series User Manual

Page 39

background image

Nomen-
clature

Parameter

FLX series

5

6

7

8

9

Max. short-circuit

current DC (at STC)

13.5 A per PV input

Min. on grid power

20 W

Efficiency

Max. efficiency

97.9%

97.9%

97.9%

97.9%

97.9%

Euro efficiency, V at

dc,r

96.1%

96.4%

96.4%

97.1%

97.2%

Other

Dimensions (H, W,

D), inverter / incl.

packaging

667 x 500 x 233 mm / 774 x 570 x 356 mm

Mounting

recommendation

Mounting plate

Weight, inverter /

incl. packaging

38 kg / 44 kg

Acoustic noise level

4

-

MPP trackers

2

Operation

temperature range

-25..60 °C

Nom. temperature

range

-25..45 °C

Storage temperature

-25..60 °C

Overload operation

Change of operating point

Overvoltage

categories

Grid: OVC III

PV: OVC II

Table 5.1 Specifications

1)

At rated grid voltage (V

ac,r

), Cos(phi)=1.

2)

To utilise the full range, asymmetrical layouts must be considered

including start-up voltage for at least 1 string. Achieving nominal

power will depend on configuration.

3)

At symmetric input configuration.

4)

SPL (Sound Pressure Level) at 1 m under normal operating

conditions. Measured at 25 °C.

Nomen-
clature

Parameter

FLX series

10

12.5

15

17

AC

|S|

Rated apparent

power

10 kVA

12.5 kVA

15 kVA

17 kVA

P

ac,r

Rated active power

1)

10 kW

12.5 kW

15 kW

17k W

Active power at

cos(phi)=0.95

9.5 kW

11.9 kW

14.3 kW

16.2 kW

Active power at

cos(phi)=0.90

9.0 kW

11.3 kW

13.5 kW

15.3 kW

Reactive power

range

0 - 6.0 kVAr

0-7.5 kVAr

0-9.0 kVAr

0-10.2 kVAr

V

ac,r

Nominal AC voltage

(AC voltage range)

3P+N+PE - 230/400 V (+/- 20 %)

Rated current AC

3 x 14.5 A

3 x 18.2 A

3 x 21.7 A

3 x 24.7 A

Technical Data

38

L00410568-03_2q / Rev. date: 2014-06-20

5

5