beautypg.com

Entries in the tool table tool.t, 1 f undamentals – HEIDENHAIN TNC 640 (34059x-01) Cycle programming User Manual

Page 531

background image

HEIDENHAIN TNC 640

531

20.1 F

undamentals

probingFeedCalc

= ConstantFeed:

The feed rate for probing remains constant; the error of measurement,
however, rises linearly with the increase in tool radius:

Measuring tolerance = r • measureTolerance1/ 5 mm, where

Entries in the tool table TOOL.T

r

Active tool radius in mm

measureTolerance1

Maximum permissible error of measurement

Abbr.

Inputs

Dialog

CUT

Number of teeth (20 teeth maximum)

Number of teeth?

LTOL

Permissible deviation from tool length L for wear detection. If the
entered value is exceeded, the TNC locks the tool (status L). Input
range: 0 to 0.9999 mm

Wear tolerance: length?

RTOL

Permissible deviation from tool radius R for wear detection. If the
entered value is exceeded, the TNC locks the tool (status L). Input
range: 0 to 0.9999 mm

Wear tolerance: radius?

DIRECT.

Cutting direction of the tool for measuring the tool during rotation

Cutting direction (M3 = –)?

R_OFFS

Tool length measurement: Tool offset between stylus center and
tool center. Default setting: No value entered (offset = tool radius)

Tool offset: radius?

L_OFFS

Tool radius measurement: tool offset in addition to offsetToolAxis
between upper surface of stylus and lower surface of tool.
Default: 0

Tool offset: length?

LBREAK

Permissible deviation from tool length L for breakage detection.
If the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm

Breakage tolerance: length?

RBREAK

Permissible deviation from tool radius R for breakage detection.
If the entered value is exceeded, the TNC locks the tool (status L).
Input range: 0 to 0.9999 mm

Breakage tolerance: radius?