Cycle parameters – HEIDENHAIN TNC 640 (34059x-01) Cycle programming User Manual
Page 428

428
Touch Probe Cycles: Automatic Datum Setting
16.8 D
A
TUM FR
OM OUTSIDE OF CORNER (Cy
c
le 414, DIN/ISO:
G414)
Cycle parameters
U
1st meas. point 1st axis
Q263 (absolute):
Coordinate of the first touch point in the reference
axis of the working plane. Input range -99999.9999 to
99999.9999
U
1st meas. point 2nd axis
Q264 (absolute):
Coordinate of the first touch point in the minor axis of
the working plane. Input range -99999.9999 to
99999.9999
U
Spacing in 1st axis
Q326 (incremental): Distance
between the first and second measuring points in the
reference axis of the working plane. Input range 0 to
99999.9999
U
3rd meas. point 1st axis
Q296 (absolute):
Coordinate of the third touch point in the reference
axis of the working plane. Input range -99999.9999 to
99999.9999
U
3rd meas. point 2nd axis
Q297 (absolute):
Coordinate of the third touch point in the minor axis of
the working plane. Input range -99999.9999 to
99999.9999
U
Spacing in 2nd axis
Q327 (incremental): Distance
between third and fourth measuring points in the
minor axis of the working plane. Input range 0 to
99999.9999
U
Measuring height in the touch probe axis
Q261
(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made. Input range
-99999.9999 to 99999.9999
U
Set-up clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to SET_UP (touch probe table). Input range 0
to 99999.9999
U
Clearance height
Q260 (absolute): Coordinate in the
touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999
X
Y
Q297
Q263
Q326
Q264
Q296
Q327
SET_UP(TCHPROBE.TP)
+
Q320
X
Y
Q261
Q260