beautypg.com

Cycle parameters, Selecting a datum table in the part program – HEIDENHAIN TNC 640 (34059x-01) Cycle programming User Manual

Page 248

background image

248

Cycles: Coordinate Transformations

1

1

.3 D

A

TUM SHIFT with D

a

tu

m T

a

bles (Cy

c

le

7,

DIN/ISO:

G53)

Cycle parameters

U

Datum shift

: Enter the number of the datum from the

datum table or a Q parameter. If you enter a
Q parameter, the TNC activates the datum number
entered in the Q parameter. Input range: 0 to 9999

Selecting a datum table in the part program

With the SEL TABLE function you select the table from which the TNC
takes the datums:

U

To select the functions for program call, press the

PGM CALL key.

U

Press the DATUM TABLE soft key

U

Select the complete path name of the datum table or

the file with the SELECT soft key and confirm your
entry with the END key.

Example: NC blocks

77 CYCL DEF 7.0 DATUM SHIFT

78 CYCL DEF 7.1 #5

Program a SEL TABLE block before Cycle 7 Datum Shift.

A datum table selected with SEL TABLE remains active until
you select another datum table with SEL TABLE or through
PGM MGT.