HEIDENHAIN TNC 640 (34059x-01) Cycle programming User Manual
Page 437

HEIDENHAIN TNC 640
437
16.1
0
D
A
TUM CIR
C
LE CENTER (Cy
c
le
416, DIN/ISO: G416)
U
Datum number in table
Q305: Enter the number in the
datum or preset table in which the TNC is to save the 
coordinates of the bolt-hole circle center. If you enter 
Q305=0, the TNC automatically sets the display so 
that the new datum is on the bolt hole center. Input 
range 0 to 2999
U
New datum for reference axis
Q331 (absolute):
Coordinate in the reference axis at which the TNC 
should set the bolt-hole center. Default setting = 0. 
Input range: -99999.9999 to 99999.9999
U
New datum for minor axis
Q332 (absolute):
Coordinate in the minor axis at which the TNC should 
set the bolt-hole center. Default setting = 0. Input 
range: -99999.9999 to 99999.9999
U
Measured-value transfer (0, 1)
Q303: Specify
whether the determined datum is to be saved in the 
datum table or in the preset table:
–1: Do not use. Is entered by the TNC when old 
programs are read in (see "Saving the calculated 
datum" on page 402).
0: Write determined datum in the active datum table. 
The reference system is the active workpiece 
coordinate system.
1: Write determined datum in the preset table. The 
reference system is the machine coordinate system 
(REF system).