beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) User Manual

Page 598

background image

598

Manual operation and setup

14.8 D

a

tu

m set

ting with a t

o

uc

h pr

obe

Finding the angle between the angle reference axis and a
workpiece edge

Select the probe function by pressing the PROBING

ROT soft key

Rotation angle: If you need the current basic rotation

later, write down the value that appears under
Rotation angle

Make a basic rotation with workpiece edge to be

compared (see "Compensating workpiece
misalignment with a 3-D touch probe" on page 585)

Press the PROBING ROT soft key to display the angle

between the angle reference axis and the workpiece
edge as the rotation angle

Cancel the basic rotation, or restore the previous basic

rotation

Set the rotation angle to the value that you previously

wrote down

Measuring the angle between two workpiece edges

Select the probe function by pressing the PROBING ROT soft key

Rotation angle: If you need the current basic rotation later, write
down the displayed rotation angle

Make a basic rotation with first workpiece edge (see "Compensating
workpiece misalignment with a 3-D touch probe" on page 585)

Probe the second edge as for a basic rotation, but do not set the
rotation angle to zero!

Press the PROBING ROT soft key to display the angle PA between
the workpiece edges as the rotation angle

Cancel the basic rotation, or restore the previous basic rotation by
setting the rotation angle to the value that you wrote down
previously

PA

–10

100

a?

a?

L?

X

Z

Y

100