HEIDENHAIN iTNC 530 (34049x-08) User Manual
Page 598

598
Manual operation and setup
14.8 D
a
tu
m set
ting with a t
o
uc
h pr
obe
Finding the angle between the angle reference axis and a
workpiece edge
Select the probe function by pressing the PROBING
ROT soft key
Rotation angle: If you need the current basic rotation
later, write down the value that appears under
Rotation angle
Make a basic rotation with workpiece edge to be
compared (see "Compensating workpiece
misalignment with a 3-D touch probe" on page 585)
Press the PROBING ROT soft key to display the angle
between the angle reference axis and the workpiece
edge as the rotation angle
Cancel the basic rotation, or restore the previous basic
rotation
Set the rotation angle to the value that you previously
wrote down
Measuring the angle between two workpiece edges
Select the probe function by pressing the PROBING ROT soft key
Rotation angle: If you need the current basic rotation later, write
down the displayed rotation angle
Make a basic rotation with first workpiece edge (see "Compensating
workpiece misalignment with a 3-D touch probe" on page 585)
Probe the second edge as for a basic rotation, but do not set the
rotation angle to zero!
Press the PROBING ROT soft key to display the angle PA between
the workpiece edges as the rotation angle
Cancel the basic rotation, or restore the previous basic rotation by
setting the rotation angle to the value that you wrote down
previously
PA
10
100
a?
a?
L?
X
Z
Y
100