HEIDENHAIN iTNC 530 (34049x-08) User Manual
Page 26

Chang
e
d functions in v
e
rsion 34049x
-0
1 since the pr
edecessor v
e
rsions
340422-xx/340423-xx
26
Changed functions in version
34049x-01 since the predecessor
versions 340422-xx/340423-xx
The layouts of the status display and additional status display were
redesigned (see "Status displays" on page 93)
Software 340 490 no longer supports the small resolution in
combination with the BC 120 screen (see "Visual display unit" on
page 87)
New key layout of the TE 530 B keyboard unit (see "Operating panel"
on page 89)
The entry range for the EULPR precession angle in the PLANE EULER
function was expanded (see "Defining the machining plane with
Euler angles: EULER PLANE" on page 485)
The plane vector in the VECTOR PLANE function no longer has to be
entered in standardized form (see "Defining the working plane with
two vectors: VECTOR PLANE" on page 487)
Positioning behavior of the CYCL CALL PAT function has been
modified (see User's Manual for Cycles)
The tool types available for selection in the tool table were increased
in preparation for future functions
Instead of the last 10, you can now choose from the last 15 selected
files (see "Choosing one of the last files selected" on page 138)