beautypg.com

Center line as datum – HEIDENHAIN iTNC 530 (34049x-08) User Manual

Page 594

background image

594

Manual operation and setup

14.8 D

a

tu

m set

ting with a t

o

uc

h pr

obe

Center line as datum

Select the probe function by pressing the PROBING

soft key

Position the touch probe at a position near the first

touch point

Select the probing direction by soft key

Probing: press the NC Start button

Position the touch probe at a position near the second

touch point

Probing: press the NC Start button

Datum:

Enter the coordinate of the datum in the menu

window, confirm with the SET DATUM soft key, or
write the value to a table (see "Writing the measured
values from touch probe cycles in datum tables", page
579
, or see "Writing the measured values from touch
probe cycles in the preset table", page 580, or see
"Storing measured values in the pallet preset table",
page 581)

To terminate the probe function, press the END key

X

Y

X+

X

Y

X+