beautypg.com

HEIDENHAIN iTNC 530 (34049x-08) User Manual

Page 592

background image

592

Manual operation and setup

14.8 D

a

tu

m set

ting with a t

o

uc

h pr

obe

Corner as datum—using points that were
already probed for a basic rotation

Select the probe function: Press the PROBING P soft

key

Touch points of basic rotation ?

: Press ENT to

transfer the touch point coordinates

Position the touch probe at a position near the first

touch point of the side that was not probed for basic
rotation

Select the probe direction by soft key

Probing: press the NC Start button

Position the touch probe near the second touch point

on the same workpiece edge

Probing: press the NC Start button

Datum:

Enter both coordinates of the datum in the

menu window, confirm with the SET DATUM soft
key, or write the values to a table (see "Writing the
measured values from touch probe cycles in datum
tables", page 579
, or see "Writing the measured
values from touch probe cycles in the preset table",
page 580, o
r see "Storing measured values in the
pallet preset table", page 581)

To terminate the probe function, press the END key

Corner as datum—without using points that
were already probed for a basic rotation

Select the probe function: Press the PROBING P soft key

Touch points of basic rotation?

: Press NO ENT to ignore the

previous touch points. (The dialog question only appears if a basic
rotation was made previously.)

Probe both workpiece edges twice

Datum

: Enter the coordinates of the datum and confirm your entry

with the SET DATUM soft key, or write the values to a table (see
"Writing the measured values from touch probe cycles in datum
tables", page 579
, or see "Writing the measured values from touch
probe cycles in the preset table", page 580, or see "Storin
g
measured values in the pallet preset table", page 581)

To terminate the probe function, press the END key

P

X=?

Y=?

X

Y

P

X

Y