Touch Probe Cycles: Automatic Kinematics Measurement
1
8
.5 PRESET COMPENSA
TION (Cy
c
le 452, DIN/ISO: G452, option)
U
Start angle A axis
Q411 (absolute): Starting angle in
the A axis at which the first measurement is to be
made. Input range: -359.999 to 359.999
U
End angle A axis
Q412 (absolute): Ending angle in the
A axis at which the last measurement is to be made.
Input range: -359.999 to 359.999
U
Angle of incid. A axis
Q413: Angle of incidence in
the A axis at which the other rotary axes are to be
measured. Input range: -359.999 to 359.999
U
Number meas. points A axis
Q414: Number of probe
measurements with which the TNC is to measure the
A axis. If input value = 0, the TNC does not measure
the respective axis. Input range: 0 to 12
U
Start angle B axis
Q415 (absolute): Starting angle in
the B axis at which the first measurement is to be
made. Input range: -359.999 to 359.999
U
End angle B axis
Q416 (absolute): Ending angle in the
B axis at which the last measurement is to be made.
Input range: -359.999 to 359.999
U
Angle of incid. in B axis
Q417: Angle of incidence
in the B axis at which the other rotary axes are to be
measured. Input range: -359.999 to 359.999
U
Number meas. points B axis
Q418: Number of probe
measurements with which the TNC is to measure the
B axis. If input value = 0, the TNC does not measure
the respective axis. Input range: 0 to 12
U
Start angle C axis
Q419 (absolute): Starting angle in
the C axis at which the first measurement is to be
made. Input range: -359.999 to 359.999
U
End angle C axis
Q420 (absolute): Ending angle in the
C axis at which the last measurement is to be made.
Input range: -359.999 to 359.999
U
Angle of incid. in C axis
Q421: Angle of incidence
in the C axis at which the other rotary axes are to be
measured. Input range: -359.999 to 359.999
U
Number meas. points C axis
Q422: Number of probe
measurements with which the TNC is to measure the
C axis. If input value = 0, the TNC does not measure
the respective axis. Input range: 0 to 12
U
No. of measuring points (4/3)
Q423: Specify
whether the TNC should measure the calibration ball
in the plane with 4 or 3 probing points. 3 probing
points increase the measuring speed:
4: Use 4 measuring points (standard setting)
3: Use 3 measuring points