HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual
Page 462

462
Touch Probe Cycles: Automatic Kinematics Measurement
1
8
.4 MEA
S
URE KINEMA
TICS (Cy
c
le
451, DIN/ISO: G451; option)
U
Start angle A axis
Q411 (absolute): Starting angle in
the A axis at which the first measurement is to be
made. Input range: –359.999 to 359.999
U
End angle A axis
Q412 (absolute): Ending angle in the
A axis at which the last measurement is to be made.
Input range: –359.999 to 359.999
U
Angle of incid. A axis
Q413: Angle of incidence in
the A axis at which the other rotary axes are to be
measured. Input range: –359.999 to 359.999
U
Number meas. points A axis
Q414: Number of probe
measurements with which the TNC is to measure the
A axis. If input value = 0, the TNC does not measure
the respective axis. Input range: 0 to 12
U
Start angle B axis
Q415 (absolute): Starting angle in
the B axis at which the first measurement is to be
made. Input range: -359.999 to 359.999
U
End angle B axis
Q416 (absolute): Ending angle in the
B axis at which the last measurement is to be made.
Input range: -359.999 to 359.999
U
Angle of incid. in B axis
Q417: Angle of incidence
in the B axis at which the other rotary axes are to be
measured. Input range: -359.999 to 359.999
U
Number meas. points B axis
Q418: Number of probe
measurements with which the TNC is to measure the
B axis. If input value = 0, the TNC does not measure
the respective axis. Input range: 0 to 12