Please note while programming – HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual
Page 264

264
Cycles: Coordinate Transformations
1
1
.3 D
A
TUM shif
t with dat
u
m tables (Cy
c
le
7,
DIN/ISO:
G53)
Please note while programming:
Danger of collision!
Datums from a datum table are always and exclusively 
referenced to the current datum (preset).
MP7475, which earlier defined whether datums are 
referenced to the machine datum or the workpiece datum, 
now serves only as a safety measure. If MP7475 = 1, the 
TNC outputs an error message if a datum shift is called 
from a datum table.
Datum tables from the TNC 4xx whose coordinates are 
referenced to the machine datum (MP7475 = 1) cannot be 
used in the iTNC 530.
If you are using datum shifts with datum tables, then use 
the SEL TABLE function to activate the desired datum table 
from the NC program.
If you work without SEL TABLE, then you must activate the 
desired datum table before the test run or the program 
run. (This applies also to the programming graphics).
Use the file management to select the desired table for 
a test run in the Test Run operating mode: The table 
receives the status S.
Use the file management in a program run mode to 
select the desired table for a program run: The table 
receives the status M.
The coordinate values from datum tables are only effective 
with absolute coordinate values.
New lines can only be inserted at the end of the table.