Cycle parameters – HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual
Page 469

HEIDENHAIN iTNC 530
469
1
8
.5 PRESET COMPENSA
TION (Cy
c
le 452, DIN/ISO: G452, option)
Cycle parameters
U
Exact calibration sphere radius
Q407: Enter the
exact radius of the calibrating ball used. Input range:
0.0001 to 99.9999
U
Setup clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF
U
Retraction height
Q408 (absolute): Input range
0.0001 to 99999.9999
Input 0:
Do not move to any retraction height. The TNC
moves to the next measuring position in the axis to
be measured. Not allowed for Hirth axes! The TNC
moves to the first measuring position in the series
A, the B, the then C
Input >0:
Retraction height in the untilted workpiece
coordinate system to which the TNC positions
before a rotary axis positioning in the spindle axis.
Also, the TNC moves the touch probe in the
working plane to the datum. The probe monitoring
is not active in this mode. Define the positioning
velocity in parameter Q253.
U
Feed rate for pre-positioning
Q253: Traversing
speed of the tool during positioning in mm/min. Input
range: 0.0001 to 99999.9999; alternatively FMAX,
FAUTO
, PREDEF.
U
Reference angle
Q380 (absolute): Reference angle
(basic rotation) for measuring the measuring points in
the active workpiece coordinate system. Defining a
reference angle can considerably enlarge the
measuring range of an axis. Input range: 0 to
360.0000
Example: Calibration program
4 TOOL CALL “TASTER“ Z
5 TCH PROBE 450 SAVE KINEMATICS
Q410=0
;MODE
Q409=5
;MEMORY
6 TCH PROBE 452 PRESET COMPENSATION
Q407=12.5 ;SPHERE RADIUS
Q320=0
;SETUP CLEARANCE
Q408=0
;RETR. HEIGHT
Q253=750
;F PRE-POSITIONING
Q380=0
;REFERENCE ANGLE
Q411=-90
;START ANGLE A AXIS
Q412=+90
;END ANGLE A AXIS
Q413=0
;INCID. ANGLE A AXIS
Q414=0
;MEAS. POINTS A AXIS
Q415=-90
;START ANGLE B AXIS
Q416=+90
;END ANGLE B AXIS
Q417=0
;INCID. ANGLE B AXIS
Q418=2
;MEAS. POINTS B AXIS
Q419=-90
;START ANGLE C AXIS
Q420=+90
;END ANGLE C AXIS
Q421=0
;INCID. ANGLE C AXIS
Q422=2
;MEAS. POINTS C AXIS
Q423=4