HEIDENHAIN iTNC 530 (340 49x-05) Cycle programming User Manual
Page 401

HEIDENHAIN iTNC 530
401
16.6 MEA
S
. CIR
C
LE OUTSIDE (Cy
c
le
422, DIN/ISO: G422)
U
Measuring height in the touch probe axis
Q261
(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made. Input range:
-99999.9999 to 99999.9999
U
Setup clearance
Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to MP6140. Input range 0 to 99999.9999,
alternatively PREDEF
U
Clearance height
Q260 (absolute): Coordinate in the
touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
-99999.9999 to 99999.9999, alternatively PREDEF
U
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
Alternatively PREDEF
U
Maximum limit of size for stud
Q277: Maximum
permissible diameter for the stud. Input range: 0 to
99999.9999
U
Minimum limit of size for the stud
Q278: Minimum
permissible diameter for the stud. Input range: 0 to
99999.9999
U
Tolerance for center 1st axis
Q279: Permissible
position deviation in the reference axis of the working
plane. Input range: 0 to 99999.9999
U
Tolerance for center 2nd axis
Q280: Permissible
position deviation in the minor axis of the working
plane. Input range: 0 to 99999.9999
X
Z
Q261
Q260