15.2 SL
O
T
CENTER REF PT (Cy
c
le
408, DIN/ISO: G408, FCL
3
function)
U
Traversing to clearance height
Q301: Definition of
how the touch probe is to move between the 
measuring points: 
0: Move at measuring height between measuring 
points 
1: Move at clearance height between measuring 
points
Alternatively PREDEF
U
Number in table
Q305: Enter the number in the
datum/preset table in which the TNC is to save the 
coordinates of the slot center. If you enter Q305=0, 
the TNC automatically sets the display so that the 
new datum is on the slot center. Input range: 0 to 
2999
U
New datum
Q405 (absolute): Coordinate in the
measuring axis at which the TNC should set the 
calculated slot center. Default setting = 0. Input 
range: -99999.9999 to 99999.9999
U
Measured-value transfer (0, 1)
Q303: Specify
whether the determined datum is to be saved in the 
datum table or in the preset table:
0: Write determined datum in the active datum table. 
The reference system is the active workpiece 
coordinate system.
1: Write determined datum in the preset table. The 
reference system is the machine coordinate system 
(REF system).