MAINTENANCE

Maintenance

Reverse Idler Port

Lubricate the reverse idler shaft and gear at every oil change (except the 500 mile/800 km

break-in service). Refer to the Periodic Maintenance Table. We recommend the use of

VICTORY Multi-Purpose Lubricant (P/N 2872863).
1. Stop the engine and position the motorcycle on

its sidestand.

2. Remove the idler port screw from the reverse

gear cover.

3. Spray the lubricant into the port hole for 2-3

seconds.

4. Raise and lower the reverse gear lever to clean

the shaft and distribute the lubricant. Repeat if

necessary. Make sure lever action is smooth

and non-binding.

5. Reinstall the port screw and torque to 50 lb-in.

(5.6 Nm).