FIO-911 O/E and E/O Converters

iControl Interface

Status

The Status window shows the status of
the four inputs to the card. One tab
shows the status of inputs A and B, and
the status of their associated SFP module,
while a second tab provides the same
information for inputs C and D.

The Inputs are identified as Electrical or
Optical, and status icons show the data
rate, Lock status, and Signal status.

The SFP module is identified by type, part
number, serial number and date code.
This is manufacturer-supplied informa-
tion, read from the module.

Data about the two optical channels is
monitored on the card, and reported in
the SFP Info table: Temperature (C),
Voltage (V), Optical Power (dBm), and
Wavelength (nm)

Reclocker and Optical

The Reclocker and Optical window allows
the user to choose whether the signal
reclockers at the inputs are ON or
BYPASSED.

Reclocker control is provided for both
electrical and optical inputs

A separate control is provided for
each of the four inputs A, B, C and D.

The default setting is ON.

For FIO-911 cards with optical outputs,
controls are provided to turn the optical
transmitters in the SFP modules ON or
OFF for outputs A, B, C and D individually.

The default setting is ON.