Resetting the controller – Grass Valley LUMO Series User Manual
Page 29
21
LUMO
User Manual
Resetting the Controller
IMPORTANT: If for any reason you cannot connect to the LUMO frame through the network
using the address you have entered:
1 Press the RESET button on the
front panel (access it through the
cutout on the panel - it is recessed
to protect against accidental acti-
vation)
2 You must keep pressing the button
for approximately 10 seconds in
order to reset the controller. During
that time, the front panel status
LED will flash yellow. You can abort
the reset at any time while the LED
is flashing by releasing the button.
3 Once the LED has stopped flashing, the LUMO-CPU-ETH will reboot, and the IP address
(along with other on-board parameters) will be reset to its factory values.
4 Follow the steps in
on page 18 to set the IP address to the required value.
If you can connect to the LUMO-CPU-ETH controller through the network, you can reset the IP
address by browsing to the controller’s IP address, and following steps 4-6 in the
Once you have applied the changes, your browser will lose contact with the controller, but you
may re-establish contact at the new IP address.
RESET button
Status LED