Epson A794-D100 User Manual
Page 98
Chapter 6: Programming Information
A794 Owner’s Guide
March 1999
92
Value of n
Remote diagnostic item
Function
Hex
Dec
31
49
Flash firmware part #
Not available, cannot write to ROM
32
50
Flash firmware part #
Not available, cannot write to ROM
33
51
Flash firmware part #,
12 digit ASCII
Return Flash firmware part #, returns 14 bytes
34
52
Flash firmware CRC
Not available, cannot write to ROM
35
53
Flash firmware CRC
Not available, cannot write to ROM
36
54
Flash firmware CRC
Not available, cannot write to ROM
37
55
Flash firmware CRC,
4 digit ASCII
Return Flash firmware CRC, returns 6 bytes
80
128
Receipt lines tally,
8 digit ASCII numeric,
max 99,999,999
Write to NVRAM
Example, send 12 bytes to printer:
GS I @ Ç00010000
To set receipt lines tally to 10,000
81
129
Receipt lines tally
Write to NVRAM, and print on receipt to
verify
Example, send 12 bytes to printer:
GS I @ ü00010000
This will print on receipt:
Receipt tally written: 10,000
82
130
Receipt lines tally
Clear receipt lines tally to 0
83
131
Receipt lines tally
Return receipt lines tally, preceded by n to
identify
Printer returns 10 bytes in above example:
â00010000
84
132
Knife cut tally,
8 digit ASCII numeric,
max 99,999,999
Write to NVRAM
85
133
Knife cut tally
Write to NVRAM, and print on receipt to
verify
86
134
Knife cut tally
Clear knife cut tally to 0
87
135
Knife cut tally
Return knife cut tally, returns 10 bytes
90
144
Hours on tally,
8 digit ASCII numeric,
max 99,999,999
Write to NVRAM
91
145
Hours on tally
Write to NVRAM, and print on receipt to
verify
92
146
Hours on tally
Clear Hours on tally to 0
93
147
Hours on tally
Return Hours on tally, returns 10 bytes
94
148
Boot firmware version
Not available