Transmit Printer ID, Remote Diagnostics Extension
Performs the remote diagnostic functions specified by n.
Each returned message is defined as:
n + data +
ASCII
GS I @ n
Hexadecimal
1D 49 40 n
Decimal
29 73 64 n
Values of n
Refer to table
Value of n
Remote diagnostic item
Function
Hex
Dec
20
32
Serial #,
10 digit ASCII
Write to NVRAM
Example, send 14 bytes to printer:
GS I @ 0x20 1234567890
21
33
Serial #
Write to NVRAM, and print on receipt to
verify
Example, send 14 bytes to printer:
GS I @ ! 1234567890
This will print on receipt:
Serial # written: 1234567890
22
34
Serial #
Not available, cannot clear Serial # item
23
35
Serial #
Return Serial #, preceded by n to identify
Printer returns 12 bytes in above example:
#1234567890
24
36
Class/model #,
15 digit ASCII
Write to NVRAM
25
37
Class/model #
Write to NVRAM, and print on receipt to
verify
26
38
Class/model #
Not available, cannot clear Class/model # item
27
39
Class/model #
Return Class/model #, returns 17 bytes
28
40
Boot firmware part #
Not available, cannot write to ROM
29
41
Boot firmware part #
Not available, cannot write to ROM
2A
42
Boot firmware part #
Not available, cannot write to ROM
2B
43
Boot firmware part #,
12 digit ASCII
Return Boot firmware part #, returns 14 bytes
2C
44
Boot firmware CRC
Not available, cannot write to ROM
2D
45
Boot firmware CRC
Not available, cannot write to ROM
2E
46
Boot firmware CRC
Not available, cannot write to ROM
2F
47
Boot firmware CRC,
4 digit ASCII
Return Boot firmware CRC, returns 6 bytes
30
48
Flash firmware part #
Not available, cannot write to ROM