Chapter 6: Programming Information
A794 Owner’s Guide
March 1999
110
Print Bar Code (continued)
Values
First Variation: String terminated with NULL Character
M
Bar Code
D
n, Length
0
UPC-A
48- 57 (ASCII numerals)
Fixed Length: 11, 12
1
UPC-E
48- 57
Fixed Length: 11, 12
2
JAN13 (EAN)
48- 57
Fixed Length: 12, 13
3
JAN8 (EAN)
48- 57
Fixed Length: 7,8
4
Code 39
48- 57,
65- 90 (ASCII alphabet),
32, 36, 37, 43, 45, 46, 47 (ASCII special
characters)
d1 = dk = 42 (start/stop code is
supplied by printer if necessary)
Variable Length
5
Interleaved 2 of 5
48- 57
Variable Length
(Even Number)
6
Codabar
65- 68, start code
48- 57,
36, 43, 45, 46, 47, 58
Variable Length
10
PDF 417
32-255
Variable Length
Second Variation Length of Byte Specified at Beginning of String
The value of m selects the bar code system as described in the table.
The variable d indicates the character code to be encoded into the specified bar code
system. See the table. If character code d cannot be encoded, the printer prints the bar
code data processed so far, and the following data is treated as normal data.